Table 1: Siting Criteria of Air Monitoring Sites/ Israel
|
Location/ Name of the site
|
Eilat
(Goldwater school rooftop)
|
Jerusalem
(Hebrew University, Earth Science Building, Givat Ram)
|
T.A
(T.A University building- Geography Department's rooftop)
|
Haifa
(Neve Shaanan
Tel Hay School rooftop)
|
|
Coordinates (UTM_E/ UTM_N)
|
688934, 3270509
|
706770, 3516647
|
669847, 3552938
|
688899, 3627219
|
|
Longitude, Latitude
|
34.56,
29.32
|
35.1,
31.45
|
34.47,
32.5
|
35,
32.45
|
|
Elevation (m)
|
55
|
765
|
30
|
220
|
|
Height (m)
|
11
|
15
|
5
|
10
|
|
Topography description
|
Public institutes in the area
|
open space
and green area
|
Residential area
|
Residential area
|
|
Population density around site/metropolitan area (person/sq/km)
|
525
|
5,641
|
10,000 |
5,088
|
|
Distance from roads (m)
|
Sth &Nth West Yotam and Hativat
Hanegev st- 40-50
|
West- Begin road and Givat Mordechai Junction- 180
|
Neighborhood road- 5
|
SW - Hagalil&Trumpeldor St. 40-50
SW Ziv commercial center 800,
NW- Grand Kanyon 1500,
S- Technion 1500
|
|
Local sources of pollution
|
|
construction at the life science building
|
|
|
|
Closest meteorological stations
|
The Israel Electric Company’s Bulding- Northern part of the city
|
Hebrew University Meteorological station is placed on the rooftop
|
T.A University Meteorological station is placed on the rooftop
|
Israeli Meteorological Service Station is situated on the roof
|
|
Proximity to Existing Air Quality Monitoring Sites
|
|
|
A station of the Ministry of Environment is situated on the rooftop
|
A station of Haifa District Municipal Association for the Environment is situated on the rooftop
|
|
Proximity of sources for particles emission
|
Transportation, airport, seaport, industrial zone, quarries
|
Transportation
|
Transportation, Riding Power Station
|
IEC,Refinery, Gadiv, Carmel Ulfinim, Nesher, Haifa Chemicals
|
|
*Pollutants that are measured in the station**
|
PM2.5
|
PM2.5
|
PM10, O3, SO2, NOX, CO
|
PM2.5, PM10, O3, SO2, NOX, CO
|
|
Meteorological parameters**
|
|
WS, WD, RH, Temp, GSR, Pre
|
RH, Temp, WS, WD, SR,UVB, PRE,
|
WS, WD, RH,
BPR, SR
|
* See also “Glossary of Terms” page
** RH- Relative Humidity; TEP- Temperature; WS- Wind Speed; WD- Wind Direction; SR- Solar Radiation; BPR- Barometric Pressure; Pre- Rain; VIS- Horizontal Visibility; CO- Carbon Monoxide; GSR- Ground Solar Radiation; NO- Nitric Oxide; NO2- Nitrogen Dioxide; O3- Ozone; PM (10; 2.5)- Particulate Matters; PRE- precipitation; SO2- Sulfur Dioxide; UVB- Ultraviolet B exposure;
Table 2: Siting Criteria of Air Monitoring Sites/ Jordan
|
Location/ Name of the site
|
Aqaba
(That Al-Sawari School)
|
Rahma
(Rahma Secondary Comprehensive School for Girls)
|
Amman
(Abu Firas Al-Hamadani Primary School)
|
Zarqa
(Zarqa Secondary School for Boys)
|
|
Coordinates (UTM_E/ UTM_N)
|
693811, 3268744
|
705950, 3311464
|
769295, 3542137
|
224399, 3548722
|
|
Longitude, Latitude
|
34.59,
29.31
|
35.7,
29.54
|
35.5,
31.58
|
36.4,
32.2
|
|
Elevation (m)
|
36
|
184
|
1039
|
648
|
|
Height (m)
|
10
|
8
|
12
|
13
|
|
Topography description
|
Residential area; No trees neither buildings of greater height surrounds the school. The roof is in a good shape and is covered with a concrete layer
Within one km no un paved road
|
No trees neither buildings of greater height surrounds the school
The roof is covered with a concrete layer
|
The school lies in Khalda area with an open view that overlooks a large part of west Amman area; commercial/ residential
|
The roof of the building is open from all sides;
commercial/ residential
|
|
Population density around site/metropolitan area (person/sq/km in 2004)
|
41
|
2
|
1972
|
1741
|
|
Distance from roads
|
300
|
300
|
250
|
300
|
|
Closest meteorological stations
|
(Aqaba Airport station)
5 km to the north of the site
|
(Aqaba Airport station)
40-45 km to the south of the site
|
(Sweileh station) 4 km to the west of the site
|
(Safe way Mall station)
5 km to the northwest of the site
|
|
Proximity to Existing Air Quality Monitoring Sites
|
ASEZA station (1 km to the east): PM10, SO2, NOX, CO, HC, NH3 and HF
|
|
Temporary measurements of gaseous pollutants in different areas in Amman (MOE and MOH)
|
Electrical Training Center (8 km to the eastern north): SO2, H2S, CO, WS and WD.
|
|
Proximity of sources for particles emission
|
Transportation and natural dust
|
Natural dust since the surrounding habitat is sandy
|
Transportation and houses heating in winter
|
Transportation and natural dust
|
|
Pollutants that are measured in the station
|
PM2.5
|
PM2.5
|
PM2.5
|
PM2.5
|
|
Meteorological parameters
|
Prevailing wind in 80% of the year is North
|
Prevailing wind: North
|
Prevailing wind: Northwest
|
Prevailing wind: Northwest
|
|
Notes
|
The distance from the nearer big PM source not less than 2 km;
The sampling site is a governmental building
To provide better security
Easier access,
Continuous supply of electricity
|
The sampling site is a governmental building
To provide better security
Easier access,
Continuous supply of electricity
|
The distance from the nearer big PM source -2 km ; The sampling site is a governmental building
To provide better security
Easier access,
Continuous supply of electricity
|
The distance from the nearer big PM source -1 km ; The sampling site is a governmental building
To provide better security
Easier access,
Continuous supply of electricity
|
Table 3: Siting Criteria of Air Monitoring Sites/ PA
|
Location/ Name of the site
|
Jerusalem
(Al-Quds University-College of Arts for women building)
|
Hebron
(Private House- Bab Al-Zawieh)
|
Nablus
(Water and Wastewater Department building)
|
|
Coordinates (UTM_E/ UTM_N)
|
709890, 3518559
|
700777, 3490403
|
712046, 3566672
|
|
Longitude, Latitude
|
35.12,
31.46
|
35.6,
31.31
|
35.14,
32.12
|
|
Elevation (m)
|
650
|
900
|
575
|
|
Height (m)
|
19
|
5
|
10
|
|
Topography description
|
Residential Area
|
Residential Area
|
Residential Area
|
|
Population density around site/metropolitan area (person/sq/km in 2004)
|
5000
|
9000
|
7000
|
|
Distance from roads
|
150
|
40-50
|
8-100
|
|
Closest meteorological stations
|
14km
|
150 m
|
200 m
|
|
Proximity to Existing Air Quality Monitoring Sites
|
No additional monitoring
equipment is placed on the roof
|
No additional monitoring
equipment is placed on the roof
|
No additional monitoring
equipment is placed on the roof
|
|
Proximity of sources for particles emission
|
Transportation
|
Transportation, and light industrial pollutions
|
transportation Others include: light industry, and tires burning for iron
|
|
Pollutants that are measured in the station
|
PM2.5
|
PM2.5
|
PM2.5
|
|
Meteorological parameters
|
WS, WD, RH, Temp, Pre
|
WS, WD, RH, Temp, Pre
|
WS, WD, RH, Temp, Pre
|
|