Table 1: Siting Criteria of Air Monitoring Sites/ Israel

 

 

 

Location/ Name of the site

Eilat

(Goldwater school rooftop)

 
Jerusalem

(Hebrew University, Earth Science Building, Givat Ram)

 
T.A

(T.A University building- Geography Department's rooftop)

Haifa

(Neve Shaanan

Tel Hay School rooftop)

 
Coordinates (UTM_E/ UTM_N)

688934, 3270509

 
 

706770, 3516647

 

669847, 3552938

 
 

688899, 3627219

 
 

Longitude, Latitude

 
34.56,
29.32
 
 
35.1,
31.45
 
 
34.47,
32.5
 
 
35,
32.45
 
 
 

Elevation (m)

 
55
765
30
220

Height (m)

 
11
15
5
10

Topography description

 

Public institutes in the area

 

open space

and green area

 

Residential area

Residential area

Population density around site/metropolitan area (person/sq/km)

 
525
5,641
 
10,000
5,088

Distance from roads (m)

Sth &Nth West Yotam and Hativat

Hanegev st- 40-50

 

West- Begin road and Givat Mordechai Junction- 180

 

Neighborhood road- 5

SW - Hagalil&Trumpeldor St. 40-50

SW Ziv commercial center 800,

NW- Grand Kanyon 1500,

S- Technion 1500

 

Local sources of pollution

 

construction at the life science building

 
 
 

Closest meteorological stations

The Israel Electric Company’s Bulding- Northern part of the city

Hebrew University Meteorological station is placed on the rooftop

T.A University Meteorological station is placed on the rooftop

Israeli Meteorological Service Station is situated on the roof

Proximity to Existing Air Quality Monitoring Sites

 
 

A station of the Ministry of Environment is situated on the rooftop

 

A station of Haifa District Municipal Association for the Environment is situated on the rooftop

 

Proximity of sources for particles emission

 

Transportation, airport, seaport, industrial zone, quarries

 
Transportation

Transportation, Riding Power Station

IEC,Refinery, Gadiv,                 Carmel Ulfinim, Nesher,  Haifa Chemicals

 

*Pollutants that are measured in the station**

 
PM2.5
PM2.5
 

PM10, O3, SO2, NOX, CO

 

PM2.5, PM10, O3, SO2, NOX, CO

 

Meteorological parameters**

 
 

WS, WD, RH, Temp, GSR, Pre

 

RH, Temp, WS, WD, SR,UVB, PRE,

WS, WD, RH,
                BPR, SR

 

* See also “Glossary of Terms” page

 

** RH- Relative Humidity; TEP- Temperature; WS- Wind Speed; WD- Wind Direction; SR- Solar Radiation; BPR- Barometric Pressure; Pre- Rain; VIS- Horizontal Visibility; CO- Carbon Monoxide; GSR- Ground Solar Radiation; NO- Nitric Oxide; NO2- Nitrogen Dioxide; O3- Ozone; PM (10; 2.5)- Particulate Matters;  PRE- precipitation; SO2- Sulfur Dioxide; UVB- Ultraviolet B exposure;

 

 

 

Table 2: Siting Criteria of Air Monitoring Sites/ Jordan

 

 

Location/ Name of the site

Aqaba

(That Al-Sawari School)

 
Rahma

(Rahma Secondary Comprehensive School for Girls)

 
Amman

(Abu Firas Al-Hamadani Primary School)

 
Zarqa
(Zarqa Secondary School for Boys)
 
Coordinates (UTM_E/ UTM_N)

693811, 3268744

 
 
 

705950, 3311464

 
 
 

769295, 3542137

 
 
 

224399, 3548722

 
 
 

Longitude, Latitude

 
34.59,
29.31
 
 
35.7,
29.54
 
 
35.5,
31.58
 
 
36.4,
32.2
 
 

Elevation (m)

 
36
184
1039
648

Height (m)

 
10
8
12
13

Topography description

 

Residential area; No trees neither buildings of greater height surrounds the school. The roof is in a good shape and is covered with a concrete layer

Within one km no un paved road

No trees neither buildings of greater height surrounds the school

The roof is covered with a concrete layer

The school lies in Khalda area with an open view that overlooks a large part of west Amman area; commercial/ residential

The roof of the building is open from all sides;

commercial/ residential

Population density around site/metropolitan area (person/sq/km in 2004)

 
41
2
1972
1741

Distance from roads

300
300
250
300

Closest meteorological stations

(Aqaba Airport station)
5 km to the north of the site

(Aqaba Airport station)

40-45 km to the south of the site

(Sweileh station) 4 km to the west of the site
(Safe way Mall station)
5 km to the northwest of the site

Proximity to Existing Air Quality Monitoring Sites

ASEZA station (1 km to the east): PM10, SO2, NOX, CO, HC, NH3 and HF

 

Temporary measurements of gaseous pollutants in different areas in Amman (MOE and MOH)

Electrical Training Center (8 km to the eastern north): SO2, H2S, CO, WS and WD.

Proximity of sources for particles emission

 

Transportation and natural dust

Natural dust since the surrounding habitat is sandy

Transportation and houses heating in winter

Transportation and natural dust

Pollutants that are measured in the station

 
PM2.5
PM2.5
PM2.5
PM2.5

Meteorological parameters

 

Prevailing wind in 80% of the year is North

Prevailing wind: North

Prevailing wind: Northwest

Prevailing wind: Northwest

Notes

The distance from the nearer big PM source not less than 2 km;

The sampling site is a governmental building

To provide better security

Easier access,

Continuous supply of electricity

The sampling site is a governmental building

To provide better security

Easier access,

Continuous supply of electricity

The distance from the nearer big PM source -2 km ; The sampling site is a governmental building

To provide better security

Easier access,

Continuous supply of electricity

The distance from the nearer big PM source -1 km ; The sampling site is a governmental building

To provide better security

Easier access,

Continuous supply of electricity

 

 

 

Table 3: Siting Criteria of Air Monitoring Sites/ PA

 

 

 

Location/ Name of the site

Jerusalem

(Al-Quds University-College of Arts for women building)

 
Hebron

(Private House- Bab Al-Zawieh)

 
Nablus

(Water and Wastewater Department building)

 
Coordinates (UTM_E/ UTM_N)
709890, 3518559
 
 
700777, 3490403
 
 
712046, 3566672
 
 

Longitude, Latitude

 
35.12,
31.46
 
 
35.6,
31.31
 
 
35.14,
32.12
 
 

Elevation (m)

 
650
900
575

Height (m)

 
19
5
10

Topography description

 

Residential Area

 

Residential Area

 

Residential Area

 

Population density around site/metropolitan area (person/sq/km in 2004)

 
5000
9000
7000

Distance from roads

150
40-50
 
8-100

Closest meteorological stations

14km
150 m
200 m

Proximity to Existing Air Quality Monitoring Sites

No additional monitoring

equipment is placed on the roof

 

No additional monitoring

equipment is placed on the roof

 

No additional monitoring

equipment is placed on the roof

 

Proximity of sources for particles emission

 
Transportation
 

Transportation, and light industrial pollutions

 

transportation Others include: light industry, and tires burning for iron

 

Pollutants that are measured in the station

 
PM2.5
PM2.5
PM2.5

Meteorological parameters

 

WS, WD, RH, Temp, Pre

 

WS, WD, RH, Temp, Pre

 

WS, WD, RH, Temp, Pre

 
 


 

 

 


English | ????? | ????
Partners:

Arava Institute for      Environmental Studies
Israel Union for      Environmental Defense
Royal Scientific Society
Jordan Society for      Sustainable      Development
Al Quds University

             Leading Staff
News:

12.12.07 | Wednesday

Preliminary results arrived from labs




Sponsors:


Copyright © 2007 The Arava Institute for Environmental Studies. All Rights Reserved ???? ?"? URL ????? ?????,????? ?????